Total suspended solids sensors and measuring systems
For optical TSS measurement
- Sensors for use with transmitter or as compact system with integrated electronics
- 1- and 4 beam technology with NIR LEDs for different concentration ranges
- For applications with hygienic requirements and many wastewater applications
OPTISENS TSS 2000
Optical total suspended solids sensor for wastewater applications
- For use with MAC 100 analytical transmitter
- For immersion
- 0…4 AU, 0…18.5 g/l (sludge); max. +70°C / +158°F; 1 bar / 14 psi
- Robust stainless steel sensor using single beam (180° NIR LED) principle, with optical sapphire glass windows
OPTISENS TSS 3000
Optical total suspended solids sensor for wastewater applications
- For use with MAC 300 analytical transmitter
- Process connection: 1¼ NPT (male)
- 0…2.5, 10 or 25 g/l (sludge); Max. +85°C / +185°F; 10 bar / 145 psi
- PP sensor using 4-beam alternating light principle, no optical windows, glass free
OPTISENS TSS 7000
Optical total suspended solids sensor for hygienic applications
- For use with MAC 300 analytical transmitter
- Process connection: Tri-Clamp 2", 3"; VARIVENT® N
- 0…1.5, 20 or 40% milk fat; Max. +85°C / +185°F; 10 bar / 145 psi
- PP or PVDF sensor using 4-beam alternating light principle, no optical windows, glass free
OPTISYS TSS 1050
Total suspended solids system for hygienic applications
- 4-wire, 4…20 mA, with head-mounted transmitter
- Process connection: G½ for hygienic adapters
- Max.: 500 EBC, 2000 FAU, 5.0 g/l, 0.4% TS; +90°C / +194°F; 10 bar / 145 psi
- Hygienic stainless steel design, CIP/SIP cleanable
OPTISYS TSS 2050
Total suspended solids system for hygienic applications
- 4-wire, 4…20 mA, with head-mounted transmitter
- Process connection: PG13.5
- Max.: 500 EBC, 2000 FAU, 5.0 g/l, 0.4% TS; +90°C / +194°F; 10 bar / 145 psi
- Hygienic stainless steel design, CIP/SIP cleanable
OPTISYS TSS 3050
Total suspended solids system for hygienic applications
- 4-wire, 4…20 mA, with head-mounted transmitter
- Process connection: G½ for hygienic adapters
- Max.: 3 AU, 6 OD, 13000 FAU, 13000 FTU, 3250 EBC, 26.65 g/l, +90°C / +194°F; 10 bar / 145 psi
- Hygienic stainless steel design, CIP/SIP cleanable
OPTISYS TSS 4050
Total suspended solids system for hygienic applications
- 4-wire, 4…20 mA, with head-mounted transmitter
- Process connection: PG13.5
- Max.: 3 AU, 6 OD, 13000 FAU, 13000 FTU, 3250 EBC, 26.65 g/l; +90°C / +194°F; 10 bar / 145 psi
- Hygienic stainless steel design, CIP/SIP cleanable