Avoidance of systematic errors
In functional safety, a distinction is made between random and systematic errors. The random faults are usually due to the failure of hardware. The systematic faults, on the other hand, are mostly due to errors in planning, commissioning or operation.
Statistically, the systematic faults are responsible for more than 90% of all malfunctions of safety loops. These faults are also referred to as "preventable" faults, since the plant operator can largely ensure that they do not occur through careful planning and operation.
Planning:
Here it must be ensured that the measuring device can really cope with the requirements of the measuring operation. Are the wetted parts designed accordingly? Are process parameters such as temperature and operating pressure correct? Are the right approvals available? Have e.g. the thermowells been calculated correctly for a temperature measurement?
Commissioning:
Is the measuring device correctly installed? If, for example, the temperature sensor does not touch the end of the thermowell, a too low temperature would be measured permanently. In the case of a high temperature shutdown, it would then trigger the safety function too late.
Operation:
Is it ensured that the process conditions assumed during the planning phase are actually maintained in practice? Does the maintenance of all components of the safety circuit correspond exactly to the manufacturer's specifications?
The sources of errors that can lead to the failure of safety functions are very diverse. Careful planning, operation and documentation of all measures within the framework of a safety management system are the best prerequisites for trouble-free plant operation.
OPTIFLUX 4400
Electromagnetic flowmeter for safety instrumented systems (SIS) and high-accuracy requirements
OPTIMASS 6400
Coriolis mass flowmeter for advanced process applications
H250 M40
Variable area flowmeter for liquids and gases
DK37 M8
Variable area flowmeter for advanced low liquid and gas flows
DK32/34
Variable area flowmeter for low liquid and gas flows
DK46/47/48/800
Variable area flowmeter for low flow gas or liquid applications and sample flow monitoring
VA40
Variable area flowmeter for basic applications
OPTISWIRL 4200
Vortex flowmeter for utility applications and energy management systems
Compact orifice plate flowmeter
Integral DP flowmeter for liquids, gases and steam
Integral orifice meter run assembly
DP flowmeter for process applications with small line sizes (down to DN15 / ½")
Averaging pitot tube flowmeter
DP flowmeter for applications with liquids, gases and steam to high-temperature applications with dust-laden gases
Wedge flowmeter
DP flowmeter for harsh process applications with abrasive and viscous media
Showing 12 of 44