Description

Hot water high level alarm

요구 사항

  • FDA and EC1935/2004 compliant as well as EHEDG and 3A
  • Applicable -20…+200°C / -4…+392°F; -1…16 barg / -14.5…580 psig

Description

Hot water temperature monitoring

요구 사항

  • Tapered tip for quick response
  • Headmount transmitter from KROHNE

Description

Hot water low level alarm

요구 사항

  • Maintenance-free ‐ can be installed in any position

Description

Hot water feed for maceration

요구 사항

  • On-site verification of flowmeter with OPTICHECK service tool
  • Meets potable water standards: ACS, DVGW, NSF, TZW, WRAS etc

Description

Water feed pressure measurement

요구 사항

  • Control of sufficient supply pressure

Description

Raw palm oil pressure measurement

요구 사항

  • Monitoring of press output pressure, press function

Description

Amount of underflow sludge

요구 사항

  • Flowmeter for low conductivity liquids (≥0.05 µS/cm)
  • Capacitive pick up, immune against electric isolation

Description

Sterilising steam

요구 사항

  • For liquids, (wet) gases, saturated and superheated steam
  • Flange or space-saving sandwich (wafer) version

Description

Decanter feed pressure measurement

요구 사항

  • Control of sufficient supply pressure

Description

Temperature profile over steriliser

요구 사항

  • Standard or customised lengths to fit the steriliser
  • Thread connection

Description

Sterilizer process pressure measurement

요구 사항

  • Pressure control/ monitoring

Description

Process line pressure measurement

요구 사항

  • Monitoring of decanter function

Description

Raw palm oil totaliser

요구 사항

  • Density of emulsion monitoring
  • Maintains operation over a wide range of gas volume fractions

Description

High level monitoring of crude palm oil

요구 사항

  • Unaffected by foam, condensate or build-up
  • Very fast response time

Description

Buffer tank level measurement

요구 사항

  • Process control

Description

Yield monitoring

요구 사항

  • Integrated temperature measurement
  • Highest OIML accuracy class of 0.3 for custody transfer (CT)

Overview

Production chain of palm oil

Instrumentation for several process steps, including extraction, refining, and fractionation

Bunches of palm fruits are delivered by truck to the site. To separate the fruits and to hydrate them by about 10%, the bunches are sterilized with steam at around 120°C, in the stripper. The bunches and leaves are then mechanically separated in the thresher. The next step is the digestion process, where the oil is released by disrupting the cell walls. The resulting hot fluid then consists of free oil, fibres and seeds. This hot fluid mixture is delivered into a decanter where water is added, to expel a mixture of oil and water into a clarifier to separate. Here the oil floats above the water and sludge at the bottom of the tank. The oil drawn off from the top is further cleaned by using another separator, where any remaining solids are removed from the oil. The sludge at the bottom still has still a certain amount of oil in it, and is processed again in another decanter. This oil is then also pumped to the buffer tank.

In palm fruit processing the electromagnetic flowmeter OPTIFLUX 7300 is our product highlight. The OPTIFLUX 7300 is the ideal flowmeter for measuring the outputs from the clarifier. Due to the non-wetted capacitive electrodes in this flowmeter, it is the perfect meter for slurries like the underflow sludge, since any coating of the pipe wall does not affect the flowmeter performance. The 7300 can also measure liquids with poor conductivity like the palm oil itself. The ceramic liner has an excellent abrasion resistance, so is unaffected by slurries containing solid materials.

이메일
연락처