Description

Level switch point mixing tank

요구 사항

  • Pump protection

Description

Level measurement mixing tank

요구 사항

  • Agitated surface

Description

Volumetric flow measurement milk

요구 사항

  • Process control

Description

Temperature control steam

요구 사항

  • Quality control

Description

Temperature control pasteurized milk

요구 사항

  • Fast response required

Description

Process pressure steam

요구 사항

  • Process control

Description

Temperature control milk

요구 사항

  • Fast response required

Description

Process pressure of milk

요구 사항

  • Process control

Description

Volumetric flow measurement milk

요구 사항

  • Process control

Description

Level measurement strainer

요구 사항

  • Agitated surface

Description

Level switch point strainer

요구 사항

  • Process control

Description

Batch meter filling machine

요구 사항

  • Repeatable filling accuracy
  • Long term stability
  • Rugged design: SIP/CIP proof and IP69K rated

Description

Process pressure pasteurised milk

요구 사항

  • Process control

Description

Flow control heat exchanger

요구 사항

  • Quality control

Description

Flow control heating water

요구 사항

  • Process control

Overview

Pasteurisation and filling in liquid milk & cream production

Heat treatment and final bottling

After homogenisation the milk enters first a mixing tank. Next step in the process is pasteurisation. Milk pasteurisation is a special type of heat treatment which secures the certain destruction of tubercle bacillus, but also any other bacteria, so that the milk is safe, and has a good shelf life. The combination of temperature and holding time is very important, as it determines the intensity of the heat treatment. The procedure is desirable from the microbiological point of view, but also has negative effects on the appearance, taste and nutritional value of the milk, as the proteins are denatured at high temperatures. The choice of the time/temperature combination is therefore a matter of optimisation, taking into account both the microbiological and the quality aspects. After the heat treatment the milk is then again homogenized and cooled down before it is stored in a buffer tank.

KROHNE offers precise and quick OPTITEMP temperature sensors and OPTIBAR pressure transmitters with hygienic connections and flush diaphragms for controlling the pasteurisation process. Also OPTIWAVE radar level meters on each tank can measure the level contactless, despite the presence of agitators. OPTISWITCH liquid level sensors are used for independent high and low level alarms, to prevent overfilling and pumps running dry. While OPTIFLUX flowmeters are used in monitoring flows in the process, BATCHFLUX electromagnetic flowmeters are used in the filling machine control systems to ensure that the exact fill volumes are dispensed to the PET bottles or cartons.

이메일
연락처